国产无遮挡裸体免费视频_欧美国产国产综合视频_亚洲香蕉久久综合网_俺去俺来也最新色官网_久久亚洲精品成人无码av无广告

News

Techcon TS5440 Needle Valve Daily Malfunctions and Troubleshooting Methods

Release Date:2017-09-21

TechconThe TS5440 needle valve, relying on the valve core to directly close the needle tube inlet of the connected dispensing needle, can achieve very precise and trace droplets, with a minimum of 0.0005ml. During the use of the Techcon TS5440 needle valve, it is inevitable to encounter some malfunctions. Techcon's high-quality agent, Shenzhen Yapude Technology Co., Ltd., has compiled some of the malfunctions and solutions encountered by the TS5440 needle valve.

fault

Possible reasons

Troubleshooting methods

No liquid flow

Liquid pressure too low

Increase the liquid pressure of the liquid storage device

The operating pressure is too low

Increase the air pressure of the valve controller
reach70 psi (4.8 bar)

Needle blockage or damage

Replace the needle

Liquid solidifies inside the valve chamber

Remove the valve and thoroughly clean it

Turn off the adjustment switch

Turn on the adjustment switch counterclockwise

Unstable liquid flow

Unstable liquid pressure

Ensure a constant liquid pressure

The operating pressure of the valve is too low

Raise the valve operating pressure of the valve controller
High to70 psi (4.8 bar)

The opening time of the valve is inconsistent

Check the valve controller to ensure it provides stability
Fixed air pressure output

Gas is trapped in the valve cover

Discharge gas from the valve

After the valve is closed, liquid still drips out and stops after a period of time

Gas is trapped in the liquid shield

Discharge gas from the valve

Leakage at the needle interface

Needle defective

Replace the needle to ensure that it is being usedTESeries Needle

展開(kāi)